510(k) Data Aggregation

    K Number
    K251856

    Validate with FDA (Live)

    Date Cleared
    2025-11-21

    (157 days)

    Product Code
    Regulation Number
    882.5890
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    1. The Z4 Li-Battery Powered OTC TENS/EMS Combination Stimulator is intended for over-the-counter (OTC) use. It integrates both TENS and EMS functions in a single unit. However, the device can only operate in one mode (either TENS or EMS) at a time; simultaneous operation of both modes is not possible.

    2. TENS is intended for temporary relief of pain associated with sore and aching muscles in the low back as well as upper and lower extremities (arm and/or leg) due to strain from exercise or normal household and work activities. (Choose TENS Modes P1 to P19 programs)

    3. EMS is intended to stimulate healthy muscles in order to improve or facilitate muscle performance. (Choose EMS Modes P20 to P30 programs)

    Device Description

    The Li-Battery powered OTC TENS/EMS Combination Stimulator, model Z4, is a four-channel electrical stimulation device intended for pain relief and muscle training. It delivers electrical current through electrodes placed on the user's skin. Each operating mode delivers a fixed, pre-configured waveform (e.g., asymmetrical bi-phasic square pulse) and output characteristics; users may only adjust intensity and treatment duration within predefined limits.

    The device primarily consists of two components: the stimulation generator and adhesive electrodes. The generator produces the stimulation current, which is delivered to the body via lead wires connected to the electrodes. Depending on the selected mode—TENS or EMS—the device helps achieve either temporary pain relief or improved muscle performance.

    The Z4 includes the following preset programs:

    • TENS Mode (Programs P1–P19): Intended for temporary relief of pain in the lower back, arms, and legs due to exercise or household/work strain. Users are advised to begin with the lowest intensity and gradually increase to a comfortable "tingling" sensation. Each program differs in waveform parameters and may produce varied sensations.

    • EMS Mode (Programs P20–P30): Designed to stimulate healthy muscles to enhance or support muscle performance. These programs cause the muscles to contract and relax. Users should start at low intensity for warm-up and increase gradually as needed.

    The Z4 device package includes the following accessories:

    • Adhesive Electrode Pads × 24
    • Lead Wires × 4
    • USB Cable × 1
    • Instruction Manual × 1
    • Carrying Case × 1
    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K201335

    Validate with FDA (Live)

    Date Cleared
    2020-10-24

    (157 days)

    Product Code
    Regulation Number
    882.5890
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    TENS: intended for temporary relief of pain associated with sore and aching muscles in the low back as well as upper and lower extremities (arm and/or leg) due to strain from exercise or normal household and work activities. (Choose TENS Modes B/N/M/SD1/SD2 as adjustable mode and P1 to P12 preset programs only for EV-906A).

    EMS: intended to stimulate healthy muscles in order to improve or facilitate muscle performance. (Choose EMS Modes C/S/A as adjustable mode and P13 to P24 preset programs only for EV-906A).

    Device Description

    Li-Battery powered OTC TENS/EMS Combination Stimulator, models EV-906/EV-906A.

    AI/ML Overview

    I am sorry, but the provided text is a 510(k) clearance letter for a medical device and does not contain the detailed information about acceptance criteria, study design, or performance metrics that you are requesting. The letter primarily states that the device is substantially equivalent to legally marketed predicate devices.

    Therefore, I cannot fulfill your request to describe the acceptance criteria and the study that proves the device meets them based on the provided input.